Al Rawan
|
Our Catalogue
|
Our Projects
|
Our Exclusive Agents
|
Contact us

Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player

  Our Products
      Pumps & Motors
Gruppo Aturia
     Submersible
     Surface
     Fire Figthing
Ritz Pumps
     ASC. Axial Split Case Pumps
     ES (End Suction Pumps)
     HP (High Pressure Pumps)
     Pressure Booster Systems
     SU (Submersible Pumps)
     SW (Sewage Wet Pumps)
      Flow Measurement Technology
Badger
     Electromagnetic flow meters
     Ultrasonic flow meters
      Soft Starters
Aucom
     Medium Voltage Soft Starters
     EMX3 soft starter
     IMS2 soft starters
     CSXi compact soft starters
     CSX soft start controllers
     ACCESSORIES
      Electric Actuators
Schiebel
     Actuators AB - Series
      Joints
Tozen
     Rubber Joints
     PTFE Joints
     Stainless Steel Joints
      Valves, Control Valves & Fitings
Z-Tide
     MULTI-FUNCTION AUTO-CONTROL
     WATER HAMMER ARRESTERS
Xiamen
     Pipe Fittings
     Valves
Tiansheng
     Butterfly Valve
     Gate Valve
     Globe Valve
     Check Valve
     Water Control Valve
     Power Station Valve
      Kompressors
Dan Kompressors
Aucom > CSX soft start controllers

Aucom > CSX soft start controllers

CSX 37-55kw
CSX 75-110kw
CSX 7-30kw
CSX 37-55kw
CSX 75-110kw
CSX soft start controllers are a reliable, easy to use soft start solution for your motor. Designed for maximum simplicity, these compact starters provide timed voltage ramp soft start and soft stop, and are perfect for fitting into your existing motor control centre.
 
The CSX s small size and integrated bypass relays make installation easy, and allow the soft starter to fit in compact enclosures with limited ventilation. Configuration is as simple as three rotary switches, and remote display and communication options allow trouble-free integration into common control networks.


 

CSX Documentation
Name File Type File size
CSX Brochure 
 
PDF
 
2.4MB


 

Model Normal Duty Heavy Duty
CSX-007 18 A 17 A
CSX-015 34 A 30 A
CSX-018 42 A 36 A
CSX-022 48 A 40 A
CSX-030 60 A 49 A
CSX-037 75 A 65 A
CSX-045 85 A 73 A
CSX-055 100 A 96 A
CSX-075 140 A 120 A
CSX-090 170 A 142 A
CSX-110 200 A 165 A

 

CSX Specifications
 
Mains Supply  
Mains voltage (L1, L2, L3)  
CSX-xxx-V4 3 x 200 VAC ~ 440 VAC (+ 10% / - 15%)
CSX-xxx-V6 3 x 200 VAC ~ 575 VAC (+ 10% / - 15%)
Mains frequency (at start) 45 Hz to 66 Hz
Rated insulation voltage 600 VAC
Form designation Bypassed semiconductor motor starter form 1
Control Voltage (A1, A2, A3)  
CSX-xxx-xx-C1 110-240 VAC (+ 10% / - 15%)
  or 380-440 VAC (+ 10% / - 15%)
CSX-xxx-xx-C2 24 VAC/VDC (± 20%)
Current consumption (during run) < 100 mA
Current consumption (at power-up)  
CSX-xxx-xx-C1 10 A
CSX-xxx-xx-C2 2 A
Inputs  
Start (terminal 01) Normally Open, 300 VAC max
Stop (terminal 02) Normally Closed, 300 VAC max
Outputs  
Main contactor (terminals 13, 14) Normally Open
  6 A, 30 VDC resistive / 2 A, 400 VAC, AC11
Environmental  
Degree of protection CSX-007 to CSX-055 IP20
Degree of protection CSX-075 to CSX-110 IP00
Operating temperatures - 10 °C to + 60 °C
Humidity 5% to 95% Relative Humidity
Pollution degree Pollution Degree 3
Vibration IEC 60068 Test Fc Sinusoidal
  4 Hz to 13.2 Hz: ± 1 mm displacement
  13.2 Hz to 200 Hz: ± 0.7 g
EMC Emission  
Equipment class (EMC) Class A
Conducted radio frequency emission 0.15 MHz to 0.5 MHz: < 90 dB (µV)
  0.5 MHz to 5 MHz: < 76 dB (µV)
  5 MHz to 30 MHz: 80-60 dB (µV)
Radiated radio frequency emission 30 MHz to 230 MHz: < 30 dB (µV/m)
  230 MHz to 1000 MHz: < 37 dB (µV/m)
   
This product has been designed as Class A equipment. Use of this product in domestic environments may cause radio interference, in which case the user may be required to employ additional mitigation methods.
EMC Immunity  
Electrostatic discharge 4 kV contact discharge, 8 kV air discharge
Radio frequency electromagnetic field 0.15 MHz to 1000 MHz: 140 dB (µV)
Rated impulse withstand voltage (Fast transients 5/50 ns) 2 kV line to earth, 1 kV line to line
Voltage dip and short time interruption 100 ms (at 40% nominal voltage)
Harmonics and distortion IEC61000-2-4 (Class 3), EN/IEC61800-3
Short Circuit  
Rated short-circuit current CSX-007 to CSX-037 5 kA
Rated short-circuit current CSX-045 to CSX-110 10 kA
Heat Dissipation  
During Start 3 watts / ampere
During Run 10 watts typical
Approvals  
IEC 60947‑4‑2
UL / C-UL UL 508
CE IEC 60947‑4‑2
CCC GB 14048.6
Lloyds IEC 60947‑4‑2

 

Al Rawan Company, Lebanon - Sea Street, Mustapha Saleh Bldg - Ghazieh, Saida
P.O. Box: 260 Saida, Lebanon - Tel: +961 7 222401 - Fax: +961 7 221799 E-mail: info@al-rawan.com | zassi@al-rawan.com
This Website is Powered By Pixel Identity